For strokes to wires or the ground plane.
Overhead ground wire lightning protection.
Transmission and distribution lines carrying large blocks of power must be permanently protected from lightning strikes and the occasional fault.
The static wire shall be grounded at every pole except manually operated group air break switch poles.
2 1 1 installation of static wire the preferred method of lightning protection of overhead sub trans mission circuits is through use of an overhead static wire.
The overhead earth wire or ground wire is the form of lightning protection using a conductor or conductors.
In special circumstances where lightning cannot be allowed to penetrate the use of tall masts and overhead ground wires used in a reduced zone model can provide additional protection.
Protection zone of ground wire is a cone with apex at the location of ground wire and surface generated by line passing through the outermost phase conductor.
Protecting things like lighting standards or trees can provide some area protection based on the zone model.
That is the lightning will bypass the overhead ground wire and strike the phase wire.
Standard for the installation of lightning protection systems 2014 standards 20.
By means of a formed copper wire grounding electrode at each pole.
For a free material quote and a designed catenary lightning protection system please contact us with your specifications and drawings.
Lightning protection of.
Conex cable s aluminum clad steel as wire overhead shield wires also referred to as ground wire provide the best protection for these vital electrical power lines.
Overhead shield wire provides lightning protection and distributed grounding important for safe operation of power lines.
Abstract in this paper a new kind of overhead transmission line ohl lightning protection system based on external ground wires is analyzed.
Opgw of which has aluminum clad steel as a component is also used for overhead shield wire.
It is attached from support to support above the transmission line and well grounded at regular interval.
Catenary or overhead ground wires can be used for lightning protection to protect open areas launch pads munition storage large haystacks and more.
Taller lines require smaller shielding angles than 30 degrees or else there will be shielding failures.
Commonly used for overhead shield wire in high corrosion areas such as industrial seashore and desert environments.
The ground wire or earthling screen used for the protection of overhead lines and power stations and substations not only provides an adequate protection against lightning but also reduces the over voltages induced electrostatically or electromagnetically but such shielding is inadequate in providing protection against travelling waves which may reach the terminal equipment and cause damage to it.
Listed items are common parts for catenary systems.